APPLYING P-201 TO VINYL SHEET PILE INTERLOCKS
Cut tip of P-201 cartridge nozzel to approximately 1/4" X 1/4" opening.
IMPORTANT - Interlock must be clean, dry and free from any oils.


The amount of P-201 required depends on gap between interlocked male and female sides when in tension. P-201 layer should be slightly more than 1/2 the gap measurement. If the measured gap is 1/8", the layer should be approximately 1/16". Apply 1/4" X 1/4" bead to provide enough P-201 for a 1/16" layer.
One cartridge will cover approximately 20~25 feet when applying a 1/16" layer.
Use a small brush to spread P-201 to the required thickness.
Photo of finished application. Note even layer of P-201.

Allow 24 + hours curing time (depends on temperature - check P-201 Data Sheet).

Protect P-201 from any water exposure prior to driving pile. Piles may be stored for upto 3 months if well protected from moisture.

IMPORTANT - Once pile has reached water level during driving, driving must be completed within 2 hours.

ALWAYS TRY APPLICATION PROCEDURE AND THREADING PROCEDURE TO ONE OR TWO PILES BEFORE TREATING ALL PILES.
CALL YOUR LOCAL REPRESENTATIVE OR 800.999.3959 FOR MORE INFORMATION

Adeka Ultra Seal USA

(800) 999-3959  |  information@adeka.com