Cut tip of P-201 cartridge nozzel to approximately 1/4" X 1/4" opening.
IMPORTANT - Interlock must be clean, dry and free from any oils.
The amount of P-201 required depends on gap between interlocked male and female sides when in tension. P-201 layer should be slightly more than 1/2 the gap measurement. If the measured gap is 1/8", the layer should be approximately 1/16". Apply 1/4" X 1/4" bead to provide enough P-201 for a 1/16" layer.
One cartridge will cover approximately 20~25 feet when applying a 1/16" layer.
Use a small brush to spread P-201 to the required thickness.
Photo of finished application. Note even layer of P-201.
Allow 24 + hours curing time (depends on temperature - check P-201 Data Sheet).
Protect P-201 from any water exposure prior to driving pile. Piles may be stored for upto 3 months if well protected from moisture.
IMPORTANT - Once pile has reached water level during driving, driving must be completed within 2 hours.
ALWAYS TRY APPLICATION PROCEDURE AND THREADING PROCEDURE TO ONE OR TWO PILES BEFORE TREATING ALL PILES.