MC-2010MN
Minimum use conditions:
Wall/slab thickness greater than 9.0"
Pipe diameter greater than 24"
Will withstand high hydrostatic head
Clean pipe and attach with glue.
MC-2005T
Minimum use conditions:
Wall/slab thickness greater than 9.0"
Pipe diameter
greater than 4.0" and
less than 24.0"
Will withstand high hydrostatic head
Peel and stick (add additional glue to pipe if
necessary)
P-201
Minimum use conditions
Wall/slab thickness greater than 4.0"
Pipe diameter
greater than 4.0" and less than 24"
Attach with glue
Hydrostatic head less than 25 feet
KBA-1510FP
Minimum use conditions
Wall/slab thickness greater than 4.0"
Pipe diameter
greater than 4.0" and less than 24"
Attach with glue
Hydrostatic head less than 25 feet
CONSTRUCTION JOINTS / COLD
JOINTS(products encapsulated in
concrete)
Non-moving below grade or water
exposed cold joints
MC-2005M
pre-formed rubber strip
20mm X 05mm
(0.79" X
0.20" - 3/4" X 3/16")
(embedded wire mesh)
Minimum Use Conditions:
Wall/slab thickness greater than 9" and less than 24" (Minimum 4" concrete coverage) - 6.5 ft wall height (check with representative for variations)
Between double row of rebar
Below grade or water present either side of wall/slab joint
Hydrostatic head less than 50 feet
Benefits:
Withstand intermittent exposure to rain or water
Expands up to 2 times by volume
Embedded wire mesh promotes vertical expansion vs longitudinal
Attach with glue or P-201 (may need screws with P-201)
Can be used on rough concrete with P-201
MC-2010MN
pre-formed rubber strip
20mm X 10mm
(0.79" X 0.39" - 3/4" X 3/8")
(embedded wire mesh )
Minimum Use Conditions:
Wall/slab thickness greater than 9.0" (10.0" recommended) Minimum 4" concrete coverage - 6.5 ft wall height (check with representative for variations)
Between double row of rebar
Below grade or water present either side of wall/slab joint
Benefits - "NSF CERTIFIED":
Withstand high hydrostatic head
Withstand intermittent exposure to rain or water
Expands up to 2 times by volume
Embedded wire mesh promotes vertical expansion vs longitudinal
Attach with screws, nails, glue, P-201 (may need nails or screws with P-201)
Can be used on
rough concrete with P-201
NSF
approved for potable water
KBA-1510FP
pre-formed rubber strip
15mm X 10mm
(0.59" X 0.39" - 9/16" X 3/8")
Minimum Use Conditions:
Wall/thickness greater than 4.0" (Minimum 1" concrete coverage
Can be used with single row of rebar or double row of rebar
Below grade or water present either side of wall/slab joint
Hydrostatic head less than 25 feet
Benefits:
Can be used outside of rebar
Low expansion pressure can be used with limited concrete coverage (1.0")
Expands approximately 25% by volume
Attach with glue or P-201 (may need screws with P-201)
Use in containment dikes
KM-3030M
Minimum Use Conditions:
Wall/slab thickness greater than 12.0" (With ˝" expansion board)
Between double row of rebar
Below grade or water present either side of wall/slab joint
Benefits:
Withstand high hydrostatic head
Withstand intermittent exposure to rain or water prior to placing concrete
Expands up to 3 times by volume
Embedded wire mesh promotes vertical expansion vs longitudinal
Attach with screws, nails, glue, P-201 (may need nails or screws with P-201)
Can be used on rough concrete with P-201
CAUTION!
The above is a
brief description of typical use and general conditions. Consult your local
representative and/or refer to
www.adeka.com
for the latest and most detailed information.
Thank you for choosing
Thank you for choosing
Adeka Ultraseal Waterstop
Unequaled in quality, function and performance
Call 800.999.3959 for
additional information
(International -
303.904.4624)
email - info@adeka.com