PIPING PENETRATIONS

MC-2010MN

Minimum use conditions:

Wall/slab thickness greater than 9.0"

Pipe diameter greater than 24"

Will withstand high hydrostatic head

Clean pipe and attach with glue. 


 

MC-2005T

Minimum use conditions:

Wall/slab thickness greater than 9.0"

Pipe diameter greater than 4.0" and
less than 24.0"

Will withstand high hydrostatic head

Peel and stick (add additional glue to pipe if necessary)


P-201

Minimum use conditions

Wall/slab thickness greater than 4.0"

Pipe diameter greater than 4.0" and less than 24"
Attach with glue

Hydrostatic head less than 25 feet


KBA-1510FP

Minimum use conditions

Wall/slab thickness greater than 4.0"

Pipe diameter greater than 4.0" and less than 24"
Attach with glue

Hydrostatic head less than 25 feet


  CONSTRUCTION JOINTS / COLD JOINTS(products encapsulated in concrete)
Non-moving below grade or water exposed cold joints



Click on icon for PDF file




 
  
 

MC-2005M

pre-formed rubber strip
20mm X 05mm
(0.79" X 0.20" - 3/4" X 3/16")
(embedded wire mesh)


Minimum Use Conditions:

Wall/slab thickness greater than 9" and less than 24" (Minimum 4" concrete coverage) - 6.5 ft wall height (check with representative for variations)

Between double row of rebar

Below grade or water present either side of wall/slab joint

Hydrostatic head less than 50 feet

Benefits:

Withstand intermittent exposure to rain or water

Expands up to 2 times by volume

Embedded wire mesh promotes vertical expansion vs longitudinal

Attach with glue or P-201 (may need screws with P-201)

Can be used on rough concrete with P-201


MC-2010MN

  pre-formed rubber strip
20mm X 10mm
(0.79" X 0.39" - 3/4" X 3/8")
(embedded wire mesh )

Minimum Use Conditions:

Wall/slab thickness greater than 9.0" (10.0" recommended) Minimum 4" concrete coverage - 6.5 ft wall height (check with representative for variations)

Between double row of rebar

Below grade or water present either side of wall/slab joint

Benefits - "NSF CERTIFIED":

Withstand high hydrostatic head

Withstand intermittent exposure to rain or water

Expands up to 2 times by volume

Embedded wire mesh promotes vertical expansion vs longitudinal

Attach with screws, nails, glue, P-201 (may need nails or screws with P-201)

Can be used on rough concrete with P-201

NSF approved for potable water


       
Embedded Wire Mesh

KBA-1510FP
pre-formed rubber strip
15mm X 10mm
(0.59" X 0.39" - 9/16" X 3/8")


Minimum Use Conditions:

Wall/thickness greater than 4.0" (Minimum 1" concrete coverage
Can be used with single row of rebar or double row of rebar
Below grade or water present either side of wall/slab joint
Hydrostatic head less than 25 feet

Benefits:

Can be used outside of rebar

Low expansion pressure can be used with limited concrete coverage (1.0")

Expands approximately 25% by volume

Attach with glue or P-201 (may need screws with P-201)

Use in containment dikes












EXPANSION JOINTS

KM-3030M

Minimum Use Conditions:

Wall/slab thickness greater than 12.0" (With ˝" expansion board)

Between double row of rebar

Below grade or water present either side of wall/slab joint

Benefits:

Withstand high hydrostatic head

Withstand intermittent exposure to rain or water prior to placing concrete

Expands up to 3 times by volume

Embedded wire mesh promotes vertical expansion vs longitudinal

Attach with screws, nails, glue, P-201 (may need nails or screws with P-201)

Can be used on rough concrete with P-201

 

 

CAUTION!
The above is a brief description of typical use and general conditions. Consult your local representative and/or refer to